How to maintain vacuum pumps, vacuum pump maintenance procedures-EUREKA

For your convenience, we have created a maintenance chart for circulating lube oil pumps. There you can familiarize yourself in more detail with the monitoring parameters during maintenance, the actions that need to be performed, the inspection intervals and the implementation methods.


controlled parameters

operations

 Check interval

Execution method

 

1

 

Check oil level

Visual inspection of the level in the inspection window

 

every day

If there is not enough oil, add oil to the pump

 

2

 

Check oil color

Perform a visual inspection in the viewing window

Once every 3 days

 

If the oil turns black, it needs to be replaced.

 

3

 

Check noise levels

Check whether there is any change in the noise when the pump is running

 

every day

 

See next troubleshooting section

 

4

 

Vibration test

Check whether the vibration increases when the pump is running

 

Once every 3 days

 

Check the tightness of the screws holding the pump

 

5

Check pump temperature

Measure pump temperature

weekly

 

Check motor fan

 

6

 

Check seals

 

Eye exam

 

weekly

 

Replace with new ones if necessary

 

7

 

Check suction filter

 

Check the filter for contamination

 

Once every 3 months

 

Clean suction filter

 

8

 

First oil change

 

Drain old oil and fill in new oil

 

After 180 hours of operation

 

Drain old oil through the drain neck and inject new oil through the filler neck

 

 

9

 

Change engine oil

 

Drain old oil and fill in new oil

 

Every 500 - 2000 hours of operation

 

Drain old oil through the drain neck and inject new oil through the filler neck

 

10

 

Replace oil filter

 

Replace filter

 

Every 500 - 2000 hours of operation

 

Replace oil filter

 

11

 

Replace exhaust filter

 

Replace filter

 

Every 500 -2000 hours of operation

 

Replace outlet air filter

 

12

 

Clean the suction valve, gas ballast valve, and fan housing

 

Clean pump

 

Every 1000 hours of operation

 

Blow out the suction valve and gas ballast valve with compressed air